1. Glossary

TermExplanation
ACCActive Cell Count. The ACC cartridge measures metabolically active cells using an enzymatic assay. ACC is the number of cells inside the ACC gate, per milliliter.
CBCColiform Bacteria Count. The CBC cartridge measures intact and metabolically active coliforms using an enzymatic assay. CBC is the number of cells inside the CBC gate, per milliliter.
CartridgeRefillable container of reagents needed for BactoSense operation
EBCE. coli Bacteria Count. The EBC cartridge measures intact and metabolically active E. coli using an enzymatic assay. EBC is the number of cells inside the EBC gate, per milliliter.
FCSFlow Cytometry Standard (FCS) is a data file standard for the reading and writing of data from flow cytometry experiments. The FCS specification has traditionally been developed and maintained by the International Society for Advancement of Cytometry (ISAC). FCS used to be the only widely adopted file format in flow cytometry.
FL1Fluorescence signal 1 (530 nm)
FL2Fluorescence signal 2 (715 nm)
FSCForward scatter, also known as Small Angle Light
Scattering. A detector measures the light scattered from microorganisms and other particles at small angles.
GateGates are tools for data analysis of a subset of data points in flow cytometry.
HNAHigh Nucleic Acid. Bacteria with a large amount of DNA which produce a strong fluorescence emission.
HNACHigh Nucleic Acid Count. The number of HNA bacteria inside the TCC or ICC gate, and above the HNA / LNA limit.
HNAP [%]High Nucleic Acid Percentage.
The percentage of HNA bacteria relative to the cell count.
ICCIntact Cell Count. Total number of intact bacteria inside of the ICC gate, per milliliter.
LNALow Nucleic Acid. Bacteria with a lower amount of DNA which produce a weaker fluorescence emission than HNA bacteria.
LNACLow Nucleic Acid Count. The number of LNA bacteria inside the TCC or ICC gate below the HNA / LNA limit.
Manual Sampling DeviceConnection module, allowing manual sampling with the BactoSense Online.
NBCEnterococcus Bacteria Count. The NBC cartridge measures intact and metabolically active enterococci using an enzymatic assay. NBC is the number of cells inside the NBC gate, per milliliter.
Online Sampling DeviceConnection module to a water line, allowing online sampling with the BactoSense Online.
SSCSide scatter, also known as Large Angle Light Scattering. A detector measures the light scattered from microorganisms and other particles at 90 degrees.
TCCTotal Cell Count. Total number of bacteria detected inside the TCC gate, per milliliter.